Back to Top

1
Hi, Guest!

Flash Point Tester Manual Pensky-Martens Closed Cup SYD-261

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Set
Harga
Rp. 123
Kami merupakan Supplier / Distributor Alat Ukur dan Alat Uji Terlengkap : Alat Pengukur PH Air, Alat Pengukur Kadar Alkohol, Alat Pengukur Debu, Alat Penguji Kadar Air, Alat Ukur Kadar Garam di Indonesia. Cek Produk dan Katalognya sekarang juga, dapatkan Penawaran Harga Terbaik dan Terpercaya. Hubungi Kami : 0813-2754-8675.

Detail Flash Point Tester Manual Pensky-Martens Closed Cup SYD-261

Flash Point Tester Manual Pensky-Martens Closed Cup SYD-261

Summary This instrument is designed and manufactured as per standards GB/ T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products in the temperature range from 40 to 360 .

Main technical features :

  1. This instrument is designed as per GB/ T261 and ASTM D93.
  2. The heating power is continuously and stepless adjustable.The power is shown visually by voltmeter. The temperature control mode is advanced and reasonable.
  3. The structure is designed small and exquisite. The stainless-steel table board is beautiful and easy to clean.
  4. Operation is easy. Test results are precise. It has been chosen as the instrument to test the closed cup flash point by many metering and detecting institutes.

Main technical specification and parameters Flash Point Tester Manual Pensky-Martens Closed Cup SYD-261 :

  1. Power supply: AC ( 220 10% ) V, 50Hz.
  2. Heating device: The heating power is continuously adjustable from 0W to 600W.
  3. Heating rate: ( 1~ 12)  / min; Controllable and adjustable.
  4. Stirring rate: ( 1) Procedure A: ( 90~ 120) RPM ( 2) Procedure B: ( 250 10) RPM
  5. Standard oil cup:
    1. Inner diameter: 50.7mm~ 50.8mm.
    2. Depth: 55.7mm~ 56.0mm
    3. The scribed line depth of capacity of testing oil: 33.9mm~ 34.3mm.
    4. Capacity of testing oil: about 70ml
  6. Igniting device:
    1. Igniting source: gas ( or other civilian fuels, the same below)
    2. Electric ignition. Gas flame diameter: 3.2mm~ 4.8mm
  7. Thermometers: Mercury-in-glass thermometer, correspond with GB/ T261-2008 and ASTM E1.
    1. Scale -5 ~ 110 , division 0.5
    2. Scale 20 ~ 150 , division 1
    3. Scale 90 ~ 370 , division 2
  8. Ambient temperature: d 35
  9. Relative humidity: d 85
  10. Total power consumption: d 650W

Untuk Harga Flash Point Tester Manual Pensky-Martens Closed Cup SYD-261 silahkan hubungi kami

Tampilkan Lebih Banyak
cv. berkah amanah
cv. berkah amanah

CV. Berkah Amanah

PREMIUM RUBY 7 Tahun
KANTOR PUSAT📍 Jl. Raya Kedungbanteng RT 1/3 Kec. Kedungbanteng, Kab. Banyumas - 53152, PURWOKERTO
Indonesia 53152
PURWOKERTO
22 / 07 / 2021
Hubungi Kami

Detail Flash Point Tester Manual Pensky-Martens Closed Cup SYD-261

Flash Point Tester Manual Pensky-Martens Closed Cup SYD-261

Summary This instrument is designed and manufactured as per standards GB/ T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products in the temperature range from 40 to 360 .

Main technical features :

  1. This instrument is designed as per GB/ T261 and ASTM D93.
  2. The heating power is continuously and stepless adjustable.The power is shown visually by voltmeter. The temperature control mode is advanced and reasonable.
  3. The structure is designed small and exquisite. The stainless-steel table board is beautiful and easy to clean.
  4. Operation is easy. Test results are precise. It has been chosen as the instrument to test the closed cup flash point by many metering and detecting institutes.

Main technical specification and parameters Flash Point Tester Manual Pensky-Martens Closed Cup SYD-261 :

  1. Power supply: AC ( 220 10% ) V, 50Hz.
  2. Heating device: The heating power is continuously adjustable from 0W to 600W.
  3. Heating rate: ( 1~ 12)  / min; Controllable and adjustable.
  4. Stirring rate: ( 1) Procedure A: ( 90~ 120) RPM ( 2) Procedure B: ( 250 10) RPM
  5. Standard oil cup:
    1. Inner diameter: 50.7mm~ 50.8mm.
    2. Depth: 55.7mm~ 56.0mm
    3. The scribed line depth of capacity of testing oil: 33.9mm~ 34.3mm.
    4. Capacity of testing oil: about 70ml
  6. Igniting device:
    1. Igniting source: gas ( or other civilian fuels, the same below)
    2. Electric ignition. Gas flame diameter: 3.2mm~ 4.8mm
  7. Thermometers: Mercury-in-glass thermometer, correspond with GB/ T261-2008 and ASTM E1.
    1. Scale -5 ~ 110 , division 0.5
    2. Scale 20 ~ 150 , division 1
    3. Scale 90 ~ 370 , division 2
  8. Ambient temperature: d 35
  9. Relative humidity: d 85
  10. Total power consumption: d 650W

Untuk Harga Flash Point Tester Manual Pensky-Martens Closed Cup SYD-261 silahkan hubungi kami

Tampilkan Lebih Banyak
Kontak Kami